Severity Status Implementation
error planned hard, depends on NET-13, VIEW-10

Looks at. Both ends' connectors (contact side), cable type, board orientation.

What it catches. An FPC or FFC link where the contact side of each connector (top or bottom), the cable type and the board orientation do not give the pin order the schematics assume.

Why it matters. A type A cable (Molex naming; Würth type 1) has its contacts on the same side at both ends, a type D (type 2) on opposite sides. With two top-contact connectors facing each other on boards that face the same way, a type A cable lands pin 1 on pin N: the order is reversed. Changing the cable type, a connector to bottom-contact, or one board's orientation each flip it again. Get one of the three wrong and every signal is on the wrong pin, often with power onto a signal.

Example. A camera board joined to a main board by a 15-pin 1 mm FFC, both connectors top-contact, both boards face up: with a type A cable the camera's 3.3 V on pin 1 lands on the main board's pin 15. Ordering a type D cable instead, or a bottom-contact connector on one side, puts pin 1 on pin 1.

How to check. For an FPC/FFC link between two netlists (NET-13): the contact side of each connector (part data), the cable type and the side each board is mounted (project, CFG-2); derive the pin mapping and compare nets per pin as in CONN-13.

Fix. Pick the cable type with the connectors, write it into both schematics and the BOM (the cable has an MPN too), and draw the link once with both ends.

References. Wikipedia, FFC "Specifications" (type A / type D, type 1 / type 2); the connector datasheets (contact position).