CONN-3 Unipolar protector on a bipolar signal¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on CFG-2 |
Looks at. Protector polarity (part data), signal range of the net.
What it catches. A unidirectional TVS or ESD diode on a line whose normal signal goes below ground: CAN, RS-485, RS-232, analog audio, a ±10 V analog input, an AC sense line.
Why it matters. A unidirectional diode is forward biased below about −0.7 V. On a line that swings negative in normal operation it clamps every negative half: an RS-485 receiver must work from −7 V to +12 V common mode, CAN sees ground offsets between nodes, RS-232 idles at −5 to −15 V. The result is a distorted or dead bus, or a diode that carries the full driver current and burns.
Example. An SMF12A (unidirectional, 12 V) on each line of an RS-485 port: fine on the bench with both nodes on one supply, but a remote node with a 3 V ground offset pulls the A line below −0.7 V on every low bit; the diode conducts, the differential signal collapses and the bus sees framing errors. The bidirectional SMF12CA, or a two-channel RS-485 or CAN ESD part (TI ESD2CAN24-Q1, ±24 V), is the right part.
How to check. Protection parts on interface nets whose range includes negative voltages: known from the transceiver class (RS-485, CAN, RS-232 parts), a net class, or a project voltage range (CFG-2). Polarity from the MPN (the A vs CA suffix of the SMx families) or the library.
Fix. A bidirectional part with a working voltage above the signal's range in both directions (SSZB130 §2.1: "must not exceed the working voltage ... in either the negative or positive direction").
References. SSZB130 §2.1, §2.2, §3.3 (CAN: ±24 V parts), §3.13 (RS-485: "must be bidirectional", −7 V to 12 V); Wikipedia, CAN bus "Layers" (common-mode range, the 0 V rail).