GND-1 Split grounds without an isolated circuit

Severity Status Implementation
warning planned mid, depends on NET-5, NET-7

Looks at. Ground nets, isolators and isolated converters.

What it catches. More than one ground net (GND, AGND, PGND, GND_ISO) where no isolator, isolated converter or transformer separates them: grounds that are split in the schematic for no functional reason.

Why it matters. A split ground only makes sense across a real isolation barrier. Without one, the two grounds are joined somewhere anyway (a 0 Ω, a regulator's pins, the chassis), and every signal that crosses between them returns through that one joint instead of right under its trace. The loop that forms radiates, picks up noise, and gives ground offsets in analog measurements: the split makes things worse than one solid plane.

Example. B135B (isolated CAN FD to USB) has a real barrier: the PS501 isolated DC/DC makes +5V0_ISO for the CAN side, and the check stays quiet. A sensor board with an AGND for its ADC front-end, joined to GND only by a 0 Ω at the regulator while the ADC's SPI lines run from the MCU across the split, is the case it reports.

How to check. Ground nets from the power structure (NET-5); for each pair, is there a part with a declared isolation barrier (digital isolator, isolated DC/DC, transformer, optocoupler, NET-7) with one side on each? If not, report the split with the parts that join them.

Fix. One ground plane, partitioned by placement (analog parts over the analog area, digital over the digital area), as MT-031 and SLYT512 recommend; split only across real isolation.

References. MT-031 "Ground and power planes", "Separating analog and digital ground planes"; SLYT512 (split vs partitioned plane, signals crossing a split); Ott chapters 3 and 17.