Skip to content

GND-3 Analog and digital grounds joined at more than one point, or not at all

Severity Status Implementation
warning runs in better_erc easy, depends on NET-5

Data it needs: graph, part classes, values, rails.

Looks at. Analog and digital ground nets, the parts that join them.

What it catches. A design with separate analog and digital ground nets (AGND, DGND) that are tied together by two or more parts (0 Ω, ferrites, net ties, a mixed-signal IC's AGND and DGND pins on different nets), or by none.

Why it matters. Split grounds need exactly one joint: with two or more, the plane between the joints carries digital return current through the analog side, which the split was meant to prevent; with none, the analog side floats and every signal crossing finds its return through parasitic paths. Both give noise and offsets that move with digital activity.

Example. A board with an ADC that has separate AGND and DGND pins (ADS1256 class), both pins tied at the part as the datasheet says, plus a 0 Ω NT1 near the regulator and a ferrite under the MCU: three joints between AGND and DGND, three loops.

How to check. Parts and net ties with one pin on each of the two ground nets, plus IC pins (AGND/DGND roles) that join them; exactly one is expected (or zero if the project says the grounds are one plane by naming only).

Fix. One joint, usually at the mixed-signal part or the supply entry; or (often better) one plane and no split (GND-1).

References. MT-031 "Separating analog and digital ground planes", "Grounding and decoupling mixed-signal ICs with low digital currents" (AGND and DGND pins joined at the part); SLYT499; SLYT512.

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only GND-3 reports on it.

gnd-3_split_ground_joints

The test schematic gnd-3_split_ground_joints The test schematic gnd-3_split_ground_joints

  warning    GND-3 #gqs     AGND is joined to GND at 3 points (FB1, NT1 and U1): digital return current flows through the analog side
                            net AGND, net GND, part FB1, part NT1, part U1
                            fix: one joint, at the mixed-signal part or the supply entry; or one plane and no split (GND-1)
  warning    GND-3 #me2     GNDA is joined to GND nowhere: the analog side floats and its signals return through parasitic paths
                            net GND, net GNDA
                            fix: one joint, at the mixed-signal part or the supply entry; or one plane and no split (GND-1)

GND-3 also fires on the test schematics of other checks: gnd-7_two_bonds.