GND-2 Suggest a Y cap between isolated grounds

Severity Status Implementation
suggestion planned mid, depends on NET-5, NET-7

Looks at. Isolated ground pairs, capacitors between them.

What it catches. Two grounds separated by an isolation barrier with no capacitor between them.

Why it matters. Isolated DC/DC converters push common-mode current across the barrier through their transformer's interwinding capacitance at the switching frequency. Without a low-impedance return next to the converter, that current returns through the cables and the environment: a large antenna, and the usual reason an isolated board fails radiated emissions. A small safety-rated capacitor across the barrier, or stitching capacitance between planes, closes the loop locally.

Example. B135B has the Y capacitor C508 across its barrier, between the USB side and the isolated CAN side fed by PS501; the notes from the B135B assembly plan one EMC sample without C508 to measure what it buys. A board with only the isolators and no capacitor across is the finding.

How to check. For each isolated ground pair (GND-1), look for a capacitor with one pin on each side; suggest one if none, and pass it to GND-6 for its rating.

Fix. A Y-rated capacitor (typically hundreds of pF to a few nF), sized for the leakage current the application allows, or interlayer stitching capacitance in the PCB.

References. SLLA368 §4 (side 1-to-side 2 capacitor, stitching capacitance); SLLA353 (CIO); IEC 60384-14 (Y class); B135 rev C change list (C508).