GND-5 Non-isolated part or structure spanning the barrier¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on NET-7, NET-5 |
Looks at. Barrier sides per net, the parts with pins on both sides.
What it catches. A part that is not an isolator with pins on both sides of an isolation barrier: a pull-up, a resistor, a capacitor without a safety rating, a protection diode, a debug header with one ground for both sides, a shield or mounting hole bonded to both grounds.
Why it matters. The barrier is only as good as its weakest link: a 10 kΩ pull-up from the isolated side to the logic rail leaks current, defeats the common-mode rejection and, at a few hundred volts, burns. A debug header with one ground pin that both sides use shorts the barrier as soon as a probe is plugged in, and the probe's ground connects the lab PC to the field side.
Example. On B153A the ISOM8600 photo-MOS relay (U101) gives an isolated contact on header pins RL1/RL2; a TVS from RL1 to the board GND "for protection" would put the relay's isolated side back on board ground.
How to check. With each net's barrier side from GND-4, every part whose pins are on both sides and which is not an isolator, an isolated converter, a transformer or a Y-rated capacitor (GND-6) is a finding.
Fix. Keep each passive on one side; protection to the local ground of its side; separate debug grounds or an isolated debug probe; shields and mounting holes to one ground, decided (GND-7).
References. SLLA284 §4.3; SLLA353 (creepage, isolation resistance RIO); Wikipedia, Galvanic isolation.