Skip to content

GND-6 Isolation rating vs the voltage the barrier must hold

Severity Status Implementation
suggestion planned mid, depends on CFG-2, NET-7

Looks at. Barrier voltage (project), isolation ratings (library).

What it catches. Isolators, isolated converters, transformers and capacitors across the barrier whose isolation rating is below what the project needs: working voltage, transient or surge voltage, or a capacitor without a Y rating.

Why it matters. Isolation ratings come in several kinds (VIOWM working, VIORM repetitive peak, VIOTM transient, VISO one-minute withstand, VIOSM surge) and the weakest part decides. A 1 kV-rated isolated DC/DC next to a 5 kV digital isolator makes a 1 kV barrier; a plain X7R capacitor across it may meet no isolation spec at all.

Example. On B135B the barrier is PS501, the isolated signal path and C508; the weakest of their ratings is the board's. C508 has to be a Y-rated part: a generic 1 nF 2 kV ceramic of the same size is not safety rated, and when it fails short it bridges the barrier.

How to check. Ratings from the library (NET-7), barrier requirement from the project (CFG-2); list each part across the barrier with its rating and the minimum, as a review table.

Fix. Parts with matching ratings (and creepage on the layout, SLLA284 §4.3); Y1 or Y2 class capacitors as the application's standard asks.

References. SLLA353 (VIOWM, VIORM, VIOTM, VISO, VIOSM definitions); SLLA284 §3.1 (parameters of interest), §4.3; IEC 60384-14.