GND-4 Net crossing an isolation barrier¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on NET-7, NET-5 |
Looks at. Isolator pin sides, the side each net belongs to.
What it catches. A net that is on both sides of an isolation barrier: a power symbol or label of one side used on the other, typically GND on a pin of the isolated side, or a non-isolated rail feeding an isolated part.
Why it matters. One wrong power symbol bridges the barrier in copper: the isolation is gone, the isolated DC/DC is shorted across, and the first ground-potential difference in the field (or the hipot test) flows through signal traces. Netlist-wise it looks perfect, the isolated part is "connected to ground".
Example. On an isolated CAN design like B135B, the transceiver's GND pin on the +5V0_ISO side given the plain GND power symbol instead of the isolated ground: the CAN ground and the USB ground are now the same net.
How to check. From the isolators' pin sides (library, NET-7), assign each net to side 1 or side 2 by propagating through non-isolating parts; a net reached from both sides is the finding, with the path.
Fix. Give each side its own ground and rail symbols (GND_ISO, +5V0_ISO) and recheck every pin of the isolated parts.
References. SLLA284 §4.3 (creepage distance), §4.5 (reference planes); Wikipedia, Galvanic isolation.