Skip to content

I2C-10 SCL and SDA pull-ups differ

Severity Status Implementation
warning runs in better_erc easy, depends on NET-4

Data it needs: graph, part classes, values.

Looks at. Pull-up values.

What it catches. Different pull-up values on SCL and SDA of one segment.

Why it matters. Rarely fatal, nearly always a mistake: a BOM swap, a value changed on one line only, or a copy from another bus. Different rise times on clock and data shrink the setup and hold margins the standard assumes, and the weaker line reaches the limit of I2C-8 first.

Example. SCL 2.2 kΩ, SDA 10 kΩ after "fixing" one line during debug.

How to check. Compare the two parallel values per segment.

Fix. Same value on both lines.

References. UM10204 §7.1.

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only I2C-10 reports on it.

i2c-10_non_equal_pull_ups

The test schematic i2c-10_non_equal_pull_ups The test schematic i2c-10_non_equal_pull_ups

  warning    I2C-10 #n1q    I2C bus /I2C: SCL pull-up R601 is 3 kΩ, SDA pull-up R602 is 3.3 kΩ
                            net /SCL, net /SDA, part R601, part R602
                            R601 = 3 kΩ (sch i2c-10_non_equal_pull_ups.kicad_sch)
                            R602 = 3.3 kΩ (sch i2c-10_non_equal_pull_ups.kicad_sch)
                            fix: the same value on both lines