I2C-10 SCL and SDA pull-ups differ¶
| Severity | Status | Implementation |
|---|---|---|
| warning | runs in better_erc | easy, depends on NET-4 |
Data it needs: graph, part classes, values.
Looks at. Pull-up values.
What it catches. Different pull-up values on SCL and SDA of one segment.
Why it matters. Rarely fatal, nearly always a mistake: a BOM swap, a value changed on one line only, or a copy from another bus. Different rise times on clock and data shrink the setup and hold margins the standard assumes, and the weaker line reaches the limit of I2C-8 first.
Example. SCL 2.2 kΩ, SDA 10 kΩ after "fixing" one line during debug.
How to check. Compare the two parallel values per segment.
Fix. Same value on both lines.
References. UM10204 §7.1.
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only I2C-10 reports on it.
i2c-10_non_equal_pull_ups¶