Skip to content

I2C-21 Bus capacitance over 400 pF

Severity Status Implementation
warning planned mid, depends on NET-4, CFG-2

Looks at. Estimated capacitance per segment.

What it catches. A segment whose estimated line capacitance exceeds 400 pF (550 pF in Fm+).

Why it matters. The rise-time budget of I2C-8 assumes Cb ≤ 400 pF; above it no legal pull-up can meet the rise time at any speed, and the drivers' VOL rises with the current they must sink. Long cables, many devices and large ESD arrays get there quickly.

Example. Twelve devices at ~10 pF each plus 1.5 m of ribbon cable (~120 pF) plus the master: ~250 pF on board, 370-400 pF with the cable, no margin.

How to check. Sum the pin capacitances (library or a default per pin), trace length if the layout is available, and connector/cable estimates from the project.

Fix. A buffer that splits the bus into two capacitive halves (SCPA054), fewer devices per segment, a shorter route, or a lower mode with its longer tr allowance.

References. UM10204 Table 11 (Cb 400 pF, 550 pF Fm+); SLVA689 §2.1; SCPA054 §3 (capacitance buffering); Wikipedia, I²C "Physical layer".