Skip to content

LVL-1 Pull-up, divider or other circuitry to a different voltage level

Severity Status Implementation
error planned mid, depends on NET-5, NET-7, IMP-10

Looks at. IO bank voltage per pin (easy for single-supply parts).

What it catches. A pull-up, pull-down divider, LED or other passive network on a pin that ends on a rail other than the one that powers that pin's IO bank: a 3.3 V pull-up on a 1.8 V pin, a divider from 5 V into a 3.3 V ADC input, a pull-up to the far side's rail on the near side of a translator.

Why it matters. The pin's ESD diode to its own supply clamps the higher level, so current flows from the higher rail through the resistor into the lower rail. That back-powers the lower domain when it is off, lifts it when it is lightly loaded, and puts the pin above its absolute maximum. A pull-up on a push-pull output to a higher rail also drives current back through the output's P-channel FET whenever the output is high (SCEA035A §3.2). The level itself "works" on the bench, which is why it survives review.

Example. A LAN8720A PHY run with VDDIO = 1.8 V, its nRST pulled up with 10 kΩ to +3V3 because the reference schematic used a 3.3 V VDDIO: 150 µA flow into the 1.8 V rail through the input clamp, and the pin sits above VDDIO + 0.3 V for its whole life.

How to check. For every resistor (or chain, NET-2) from a pin to a rail, compare the rail voltage (NET-5) with the supply of that pin's bank. For a single-supply part the bank is the one VDD net; for multi-bank parts (FPGAs, SoCs, MCUs with VDDIO2) the bank of each pin must come from part data (NET-7, IMP-10).

Fix. Pull to the pin's own bank rail; across domains use a translator, an open-drain buffer with the pull-up on the receiving side, or a divider sized for the lower side.

References. SCEA035A §3.2; AN4899 §6.2; Wikipedia, Logic level.