Skip to content

LVL-10 Higher-voltage output into a lower-voltage input above its absolute maximum

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. Real rail voltages, per-pin tolerance (FT).

What it catches. An output on a higher rail driving an input whose absolute maximum is its own VDD + 0.3 V (or similar): 5 V into a 3.3 V pin that is not 5 V tolerant, 3.3 V into a 1.8 V pin.

Why it matters. The input clamp diode conducts; the driver's output current flows into the lower rail and the pin, which is damage in the long run and back-powering in the short run (the lower domain stays half alive when it should be off). "5 V tolerant" is not a property of the whole MCU: on STM32 it holds only for FT pins, only in input mode, only with VDD present (below 3.6 V otherwise) and only with no analog function enabled (AN4899 §5.2.2, §6.3).

Example. B200A's "1V8" rail +1V8_LDO is made by a TLV70233, a fixed 3.3 V LDO, so the I2C low path and every "1.8 V" IO option put about 3.2 V on a device that expects 1.8 V; the firmware had to stop offering 1.8 V until the part is swapped (rev B change list). A check that trusts the net name passes it.

How to check. Take the real voltage of each rail from its source (the regulator's part or feedback divider, not the net name; NET-5 sources), then compare a driver's VOH(max) with the receiver pin's absolute maximum and tolerance class (NET-7).

Fix. A translator or a series resistor plus clamp sized for the injected current; or move to a tolerant pin (MUX-8); or fix the rail.

References. AN4899 §5.2.2, §6.3; SCEA035A §5 (overvoltage-tolerant inputs); B200 rev B change list (U1602).