Skip to content

LVL-2 1V8 output to 3V3 input and similar: compare thresholds

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. Output VOH and input VIH per pin, bank voltages.

What it catches. A push-pull output from a lower-voltage domain driving an input of a higher-voltage domain whose VIH is above the driver's VOH(min).

Why it matters. CMOS inputs typically switch at a fraction of their own supply: 0.7 · VDD for VIH on many parts, 2.31 V at 3.3 V. A 1.8 V output never gets there; the input sits in the undefined region, reads randomly, and draws shoot-through current (both input FETs half on). Some parts pass on the bench because their real threshold is near VDD/2, and fail on the next lot or at temperature.

Example. A 1.8 V SoC's UART TX into a 3.3 V USB-UART bridge whose RXD needs VIH = 2.0 V: characters drop at cold and on some boards only. A 3.3 V MCU into a 5 V 74HC input (VIH 3.5 V at 5 V) is the same mistake one level up; a 74HCT input (TTL thresholds, VIH 2.0 V) would accept it (SCEA035A §6).

How to check. For each net with one driver and one or more inputs in different domains, compare VOH(min) of the driver at its bank voltage with VIH(min) of each input at its own (NET-7). Without part data, fall back on the 0.7 · VDD rule and report it as an estimate.

Fix. A translator (LVC1T45 class for one direction), a receiver with TTL-compatible or fixed thresholds (74HCT, 74LVC at the higher supply with 5 V tolerant inputs driven from 3.3 V), or move the signal to a bank at the right voltage (LVL-6).

References. SCEA035A §2 and §6; Wikipedia, Logic level; AoE3 chapter 12.