LVL-13 Level shifter output enable floating, or enabled before both of its rails are up¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-7, NET-8 |
Looks at. OE pin role, power-up order of the two rails.
What it catches. A translator's OE (or ~OE) with no pull to the disabled state, or tied enabled while its two supplies can come up in either order.
Why it matters. With OE floating the outputs are enabled or not by chance, and a floating OE draws extra supply current (SCEA044 §5). Enabled while one rail is still ramping, a translator can glitch its outputs or pass the other side's state as a wrong level. TI asks for OE pulled to GND and enabled only once VCCA and VCCB are stable (TXS0102 §8.3).
Example. B153A does it right: the TXS0102's OE is on PB2 with a 10 kΩ pull-down (R213), so the shifter is off through reset and while the MCU is halted. The same part with OE tied to VCCA would enable the instant 3.3 V is up, before V_SBU is selected.
How to check. The OE net needs a pull to the disabled level or a driver valid at reset (NET-7); a tied OE is a finding when the two rails have no guaranteed order (NET-8). The floating half runs without power states.
Fix. Pull OE to its disabled level; drive it from a GPIO after both rails are up, or from the later rail's power-good.
References. TXS0102 §8.3; SCEA044 §5; SCEA043 §4.