LVL-6 A better suited bank exists for the net voltage or target bank voltage

Severity Status Implementation
suggestion planned hard, depends on NET-7, NET-12, IMP-10

Looks at. Bank of every pin, pin-swap freedom, net voltages.

What it catches. A signal routed to an IO bank at the wrong voltage (and so through a translator or a divider) while a free, function-compatible pin exists on a bank already at the right voltage.

Why it matters. FPGAs, CPLDs/SPLDs and SoCs often have banks at 1.8 V and 3.3 V on the same package side. Moving a signal to the matching bank removes a translator, its delay and its failure modes, and frees space.

Example. On an SPLD the +3V3 side is used for a 1.8 V sensor interface through a TXS0104, while the +1V8 bank on the same side as the connector has free pins: move the four lines and drop the translator.

How to check. For every translated or divided signal, list free pins on banks at the signal's voltage that can carry its function (NET-12, bank data from IMP-10), preferring the same package side.

Fix. Re-assign the pins (and re-check MUX-1/MUX-2 for the new ones), then delete the translator.

References. SCEA035A §1-2 (cost of translation); vendor bank tables of the part.