Skip to content

LVL-8 Signal not referenced to GND

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. Each part's ground reference, rails.

What it catches. A logic signal crossing between parts whose ground pins are on different nets: an inverting buck-boost (a buck IC whose ground pin sits on the negative output), a high-side gate driver referenced to the switch node, a part on an isolated ground.

Why it matters. A logic level is a voltage against the receiver's own ground. A buck IC used as an inverting buck-boost has its GND pin at −Vout, so an EN driven by a 3.3 V MCU against board ground arrives as 3.3 V + |Vout| at the IC: it may exceed EN's absolute maximum, and "low" (0 V) is still |Vout| above the IC's ground, above its VIH, so the converter can never be turned off.

Example. A buck regulator wired as an inverting buck-boost to make −5 V: its GND pin on -5V, EN from an MCU GPIO. With the GPIO low, EN sees +5 V against the IC's ground and the rail stays on; with it high, EN sees 8.3 V.

How to check. For every net that connects pins of two parts, compare the nets on their ground pins (NET-5, ground pins from NET-7); report when they differ and no level-shifting part (isolator, PNP/NPN shifter, optocoupler) sits between.

Fix. A level shift referenced to the IC's ground (a PNP or a small FET pair, an optocoupler), or a part with an enable referenced to board ground.

References. The regulator's datasheet section on inverting operation; AoE3 chapter 12.