Skip to content

NAME-1 Inconsistent naming of inverted signals: suggest one notation

Severity Status Implementation
suggestion runs in better_erc easy, depends on netlist

Data it needs: graph.

Looks at. Net names.

What it catches. A schematic that marks active-low signals in several ways at once: RST_N, nIRQ, ~{CS}, OE#, RESETn.

Why it matters. A reader has to know every convention to see the polarity, and a tool must recognise all of them; a mix also hides the nets that carry no marker at all (NAME-10). Picking one is cheap and makes polarity mistakes (LOGIC-8) visible at a glance.

Example. ~HUB_RESET, SPI_CS_N and nPWR_FAULT on one board: three spellings, and a search for active-low nets finds a third of them.

How to check. Classify net names by marker style (overbar markup, _N/_n suffix, n prefix, # suffix); more than one style in a project is a finding, listed by style.

Fix. One style for the project; KiCad's overbar markup ~{...} renders well on the sheet, _N survives every export and tool.

References. Wikipedia, Logic level (active-low notations); KiCad Eeschema "Text markup".

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only NAME-1 reports on it.

name-1_inverted_signal_styles

The test schematic name-1_inverted_signal_styles The test schematic name-1_inverted_signal_styles

  suggestion NAME-1 #hf7    active-low signals are marked in 3 styles: ~{X} (1: /~{HUB_RESET}); X_N (2: /FLASH_WP_N, /SPI_CS_N); nX (1: /nPWR_FAULT)
                            net /nPWR_FAULT, net /~{HUB_RESET}
                            fix: one style for the project, X_N as most nets use it (`~{...}` renders as an overbar, `_N` survives every tool)

NAME-1 also fires on the test schematics of other checks: wire-2_similar_names.