Skip to content

NAME-8 Fixed-voltage name on a net that is not fixed

Severity Status Implementation
warning planned mid, depends on NET-5, CFG-2

Looks at. Rail sources and what can change them (PD, switches; NET-5, CFG-2).

What it catches. A net named with a fixed voltage (+5V) whose source is not fixed: USB VBUS behind a PD sink, a battery, an adjustable regulator, an external supply.

Why it matters. Everyone downstream trusts the name: parts get rated for 5 V, a header pin is labelled 5 V, a user plugs a 5 V-only device into it. With PD the port can negotiate up to 20 V. better_erc's checks also take the name's voltage as fact.

Example. B153A's header pin 10 is named and silkscreened +5V, but it is the receptacle VBUS through the switch Q102: 5 V by default, up to 20 V after PD. The rev B change list renames the net and silk to VBUS_SW.

How to check. Rails named with a voltage whose source is a USB receptacle with a PD controller, a battery, an adjustable regulator or a connector the project marks as variable; report the name with the range.

Fix. Name the net by what it is (VBUS_SW, VBAT, VIN), and rate everything on it for the full range (RATE-19).

References. B153 rev B change list (+5V to VBUS_SW); B153A schematic review §10 (header J101); catalogue RAIL-3, RATE-19.