NAME-6 Suggest per page designators; highlight missing ones¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | runs in better_erc | easy, depends on netlist (sheet path per component |
Data it needs: graph.
Looks at. Designators and the sheet each part is on.
What it catches. A multi-sheet design numbered across the whole project instead of per sheet (R1xx on sheet 1, R2xx on sheet 2, ...), and, where per-sheet numbering is used, parts whose number does not match their sheet.
Why it matters. Per-sheet numbers tell anyone holding the board or the BOM where in the schematic a part lives: R607 is on sheet 6. Revisions also stay stable: adding a part on sheet 3 does not shift the numbers on sheet 5. Our boards number this way (B200A's MCU sheet holds U1801-U1803, R1802 and R1807).
Example. A part moved from sheet 2 to sheet 7 keeps R214; a reviewer looks for it on sheet 2.
How to check. Compare each designator's hundreds (or thousands) with its sheet number; report mismatches, and suggest the scheme when the project uses flat numbering.
Fix. KiCad's annotation can start numbering at the sheet number × 100 or × 1000.
References. KiCad Eeschema "Annotation tool" (numbering from the sheet number × 100 or × 1000).
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only NAME-6 reports on it.
name-6_per_sheet_designators¶