Skip to content

NAME-6 Suggest per page designators; highlight missing ones

Severity Status Implementation
suggestion runs in better_erc easy, depends on netlist (sheet path per component

Data it needs: graph.

Looks at. Designators and the sheet each part is on.

What it catches. A multi-sheet design numbered across the whole project instead of per sheet (R1xx on sheet 1, R2xx on sheet 2, ...), and, where per-sheet numbering is used, parts whose number does not match their sheet.

Why it matters. Per-sheet numbers tell anyone holding the board or the BOM where in the schematic a part lives: R607 is on sheet 6. Revisions also stay stable: adding a part on sheet 3 does not shift the numbers on sheet 5. Our boards number this way (B200A's MCU sheet holds U1801-U1803, R1802 and R1807).

Example. A part moved from sheet 2 to sheet 7 keeps R214; a reviewer looks for it on sheet 2.

How to check. Compare each designator's hundreds (or thousands) with its sheet number; report mismatches, and suggest the scheme when the project uses flat numbering.

Fix. KiCad's annotation can start numbering at the sheet number × 100 or × 1000.

References. KiCad Eeschema "Annotation tool" (numbering from the sheet number × 100 or × 1000).

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only NAME-6 reports on it.

name-6_per_sheet_designators

The test schematic name-6_per_sheet_designators The test schematic name-6_per_sheet_designators

  suggestion NAME-6 #2bc    R214 is on page 3 (/Power/), outside its series 3xx
                            sheet /Power/, part R214
                            fix: re-annotate the part with its sheet's series, or move it back