Skip to content

NAME-12 Unannotated or duplicate reference designators

Severity Status Implementation
error runs in better_erc easy, depends on netlist

Data it needs: graph.

Looks at. Reference designators.

What it catches. Parts still carrying R?, U? (never annotated), or two parts with the same designator.

Why it matters. The designator is the key that joins schematic, layout, BOM and placement file. An unannotated part may not reach the layout at all, and duplicates merge two parts into one in the netlist or the BOM: one of them is never bought, or both pads get the same net.

Example. A block copied between two projects with its designators, pasted next to parts already called R12 and C5: the netlist export resolves the clash by dropping one, and the layout misses a capacitor.

How to check. Designators ending in ?, and designators used more than once across the hierarchy (units of one multi-unit part excepted).

Fix. Annotate the whole schematic (KiCad's annotation tool), keeping existing numbers on later revisions.

References. KiCad Eeschema "Annotation tool"; Wikipedia, Reference designator.

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only NAME-12 reports on it.

name-12_designators

The test schematic name-12_designators The test schematic name-12_designators

  error      NAME-12 #akq   C5 is placed 2 times (on /, /): two parts share one designator
                            part C5
                            fix: re-annotate the duplicates; a netlist or BOM merges them into one part
  error      NAME-12 #0ad   R? (10k) is not annotated
                            part R?
                            fix: annotate the schematic (keep existing numbers on later revisions)