Skip to content

NAME-13 Power net name not in the +<voltage>_<source or group> form

Severity Status Implementation
suggestion runs in better_erc mid, depends on NET-5

Data it needs: graph, rails.

Looks at. Net names, the power structure (NET-5).

What it catches. A power net that shares its voltage with another rail of the board and is not named +<voltage>_<source or group> with V as the decimal point (+3V3_LDO, +3V3_BUCK, +1V8_REF, -5V_CP). A board with a single rail of a voltage may keep the plain +3V3. An adjustable rail has no fixed voltage, so +<name>_ADJ (+VIO_ADJ) is accepted in its place.

Why it matters. At a power symbol the name is all the reader sees: the suffix tells two 3.3 V rails apart and says which regulator to look at; VCC or V3V3 sends the reader to the power tree for every pin. House style (Roman, 31 Oct 2026); the drawing guide has the forms.

How to check. Rails and their voltages from NET-5; group by voltage; in a group of two or more, each name must parse as sign, voltage with V as decimal point, _, and a suffix, or as sign, a name, and the suffix _ADJ.

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only NAME-13 reports on it.

name-13_power_net_form

The test schematic name-13_power_net_form The test schematic name-13_power_net_form

  suggestion NAME-13 #hnc   +3V3 is one of 2 rails of 3.3 V, without its source in the name
                            net +3V3
                            fix: name it +<voltage>_<source or group>, like +3V3_LDO

NAME-13 also fires on the test schematics of other checks: dbg-10_crowded_rail, dec-1_no_decoupling, dec-4_ferrite_beads, i2c-4_pull_up_to_signal, i2c-7_segments, lvl-7_several_rails, pin-3_unprotected_outputs, pin-4_unfused_inputs, pin-6_unfiltered_inputs, rail-18_parallel_regulators, rail-19_unfiltered_analog_supply, rail-1_unpowered_pins, rail-5_unsourced_rail, test-2_duplicate_test_points, test-4_rail_test_points, wire-2_similar_names.