USB-16 Type-C receptacle with VBUS or GND pins unconnected¶
| Severity | Status | Implementation |
|---|---|---|
| error | runs in better_erc | easy, depends on netlist |
Data it needs: graph, part classes, rails.
Looks at. Receptacle pins.
What it catches. A Type-C receptacle with one of its VBUS pins (A4, A9, B4, B9) or ground pins (A1, A12, B1, B12, and the shell where the footprint counts it) not on the VBUS or GND net.
Why it matters. The spec requires all VBUS pins bussed together and all ground pins bussed together at the mounted receptacle. The cable carries the current through all of them; with half the contacts open, each one left carries double, the 3 A or 5 A rating no longer holds, contacts heat, and the IR-drop budget is gone. A missing ground on one row also breaks the return path next to the high-speed pairs of that row.
Example. A 16-pin USB 2.0 receptacle symbol with the B-row VBUS pins as separate pins that were never wired (the KiCad ERC does not complain about unconnected passive pins): at 3 A the remaining two contacts each carry 1.5 A, and the receptacle gets hot.
How to check. All pins named VBUS on a Type-C connector on one net, all GND pins on one ground net.
Fix. Connect every VBUS and GND pin, with copper sized for the current.
References. Type-C Table 3-4 notes 2 and 3, Table 3-5 notes 4 and 5 (all VBUS and all ground pins bussed together), §4.4.1 (IR drop).
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only USB-16 reports on it.
usb-16_vbus_gnd_pins¶
error USB-16 #gsq Type-C receptacle J3: VBUS pins not bussed together: on 2 nets, /VBUS_B and VBUS; the contacts left carry the cable's whole current
net /VBUS_B, net VBUS, part J3
fix: connect every VBUS and GND contact, with copper sized for the current
error USB-16 #jkk Type-C receptacle J1: GND pins not bussed together: J1.B12 (GND) connected to nothing; the contacts left carry the cable's whole current
part J1, pin J1.B12
fix: connect every VBUS and GND contact, with copper sized for the current
error USB-16 #7w2 Type-C receptacle J1: VBUS pins not bussed together: J1.B4 (VBUS) and J1.B9 (VBUS) connected to nothing; the contacts left carry the cable's whole current
part J1, pin J1.B4, pin J1.B9
fix: connect every VBUS and GND contact, with copper sized for the current
error USB-16 #xdd Type-C receptacle J3: GND pins not bussed together: J3.A12 (GND) connected to nothing; the contacts left carry the cable's whole current
part J3, pin J3.A12
fix: connect every VBUS and GND contact, with copper sized for the current
USB-16 also fires on the test schematics of other checks: gnd-7_two_bonds.