Skip to content

USB-5 USB device with more than 10 µF on VBUS

Severity Status Implementation
warning planned mid, depends on NET-5, NET-10, IMP-6

Looks at. Port role, capacitors on VBUS up to the first current limit.

What it catches. A device (upstream-facing) port whose VBUS carries more than 10 µF of capacitance, directly or through a regulator, without an inrush limiter in front of it.

Why it matters. USB 2.0 limits what a device may show at attach to 10 µF in parallel with 44 Ω, so the host's VBUS droops by no more than 330 mV and the other ports on the hub stay up. A larger capacitance charges from the host's bulk at attach: the host's port droops, other devices on the same hub reset or disconnect, and an over-current limit may trip. More bulk is allowed only behind a soft-start or a current limit.

Example. On our bench, B153A switched its plug VBUS hard onto a B129A with more than 110 µF on its input: the dongle's own supply dipped and the hub reset. A 10 Ω in series in the wire cured it; the rev B change list asks for a soft start on that switch. The same B129A plugged into a laptop port droops the laptop's port in the same way.

How to check. Decide the port role (Rd on CC, a Type-B or Micro-B receptacle, a device PHY); sum the capacitance on the VBUS net and on nets reached through ferrites, 0 Ω ties and regulators that have no soft start, up to the first load switch or limiter; compare with 10 µF.

Fix. Keep ≤ 10 µF on VBUS and put the rest behind a load switch with controlled rise time (AN5225 suggests a gate-drain capacitor of 100 pF per 10 µF of load); or a dedicated inrush limiter.

References. USB 2.0 §7.2.4.1 (inrush current limiting: 10 µF ∥ 44 Ω, 330 mV droop); AN5225 §14.3.1 (sink mode: Cvbus 2.2 µF, bulk behind a switch), §14.3.4 (limit the inrush current in sink mode).