USB-4 USB shield not connected, or reaching no ground¶
| Severity | Status | Implementation |
|---|---|---|
| warning | runs in better_erc | easy, depends on netlist |
Data it needs: graph, part classes, values, rails.
Looks at. Connector shell pins, what they connect to.
What it catches. The shell or shield pins of a USB connector left unconnected, or on a net that reaches no ground.
Why it matters. The cable shield only works when it is terminated with low impedance at the frequencies that matter. A floating shell is an antenna for the cable's common-mode current, and an ESD strike on it has no path. The Type-C specification asks for the receptacle shell and mid-plate to be soldered to the PCB ground plane with several tails, and for the receptacle to be bonded to a metal chassis where there is one.
Example. A Type-C receptacle whose four shell tabs have no net, because the symbol's shield pin was never wired: the cable shield ends at the board.
How to check. Pins named or typed as shield or shell (SH, S1-S4, SHIELD) on USB connectors: unconnected, or on a net that is no ground and that no two-pin part joins to one. A shell on a ground, or joined to one through a part, is judged by GND-7 against the product's enclosure (grounds.enclosure).
Fix. Shell straight to the ground plane with several vias, or to the chassis net in a metal case (GND-7).
References. Type-C §3.10.1 (EMC management: mid-plate and shell to the PCB ground plane, receptacle to chassis); Ott §2.15, §3.3, §16.2; AN4879 §2.3 (ESD and EMI).
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only USB-4 reports on it.
usb-4_shield¶
warning USB-4 #2hm USB connector J3: shell J3.6 (Shield) connected to nothing: the cable shield ends in an antenna and ESD on the shell has no path
part J3, pin J3.6
fix: shell straight to the ground plane with several vias, or to the chassis net in a metal case (GND-7)
USB-4 also fires on the test schematics of other checks: lib-31_mount_attribute.