USB-9 CC1 and CC2 tied together on a receptacle¶
| Severity | Status | Implementation |
|---|---|---|
| error | runs in better_erc | easy, depends on netlist |
Data it needs: graph, part classes, values.
Looks at. CC pins of the receptacle.
What it catches. A Type-C receptacle whose CC1 (A5) and CC2 (B5) are on the same net, usually to save a resistor.
Why it matters. The source tells the orientation from which CC pin is terminated, and an e-marked or active cable presents Ra on the other one (the VCONN pin of its plug). With both pins joined, the cable's Ra (800 Ω-1.2 kΩ) lands in parallel with the sink's Rd: the source sees Ra/Ra or Ra plus too-low Rd and does not turn VBUS on. A source that supplies VCONN puts it straight onto the sink's CC net. Orientation detection and PD are gone.
Example. The Raspberry Pi 4 (first revisions) shared one CC pull-down, R79, between both CC pins. With e-marked cables (a MacBook charger's cable, for example) the charger saw Ra and never powered the Pi; with plain cables it worked, which is why it shipped.
How to check. CC1 and CC2 pins of one receptacle on the same net, directly or through a 0 Ω tie.
Fix. A separate 5.1 kΩ to GND on each CC pin, or a controller with two CC pins.
References. Type-C §2.5 (VCONN on the CC pin not used by the cable), §4.5.1.1 (plug flip-ability), Table 4-10 (source perspective), Table 4-29 (Ra); Tyler Ward, "Pi4 not working with some chargers (or why you need two cc resistors)" (2019), scorpia.co.uk.
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only USB-9 reports on it.
usb-9_cc_tied¶
error USB-9 #z59 Type-C receptacle J2: J2.A5 (CC1) and J2.B5 (CC2) joined by R2: an e-marked cable's Ra lands on the sink's Rd and the source does not turn VBUS on; orientation detection and PD are gone
net /CC1_J2, net /CC2_J2, part J2, part R2, pin J2.A5, pin J2.B5
fix: a separate 5.1 kΩ to GND on each CC pin, or a controller with two CC pins
error USB-9 #nyr Type-C receptacle J1: J1.A5 (CC1) and J1.B5 (CC2) on one net, /CC_J1: an e-marked cable's Ra lands on the sink's Rd and the source does not turn VBUS on; orientation detection and PD are gone
net /CC_J1, part J1, pin J1.A5, pin J1.B5
fix: a separate 5.1 kΩ to GND on each CC pin, or a controller with two CC pins