USB-2 No overvoltage protection on Type-C CC and SBU¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-7, NET-10 |
Looks at. CC and SBU nets, protection part type (library).
What it catches. CC1, CC2, SBU1 or SBU2 of a Type-C connector reaching an IC pin with no part rated for a short to VBUS in between: no OVP switch (TPD6S300A, TCPP01/03, DPO2036 class) and no 24 V-capable clamp.
Why it matters. On a Type-C receptacle CC and SBU sit right next to VBUS (A4/A5 and B8/B9). A tilted plug, a bent contact, debris or a non-compliant cable can short them, and with USB PD VBUS may be 20 V. Ringing on a hot short can reach twice the settled voltage. A CC/PD controller or MCU pin rated 5.5 V dies, and with it the port. At 5 V only, most parts survive; the risk is real once the port negotiates more.
Example. B153A was built with both DPO2036 (U402 receptacle, U501 plug) removed and their footprints shorted across. A CC or SBU short to a 20 V PD VBUS then lands straight on PA8, PB15 (UCPD1), PA13, PA14 (SWD) on the receptacle side, PD0 and PD2 on the plug side. The board reference warns the firmware and the user; rev B has to decide the protection again.
How to check. Follow each CC and SBU net from the connector to the first IC pin; a part on the path must be of the OVP-switch class, or the IC pin itself must be rated for the highest VBUS the port can see (from the project or from a PD controller on the board).
Fix. A Type-C port protector on CC and SBU (TPD6S300A for both, TCPP01-M12 for sinks); for a 5 V-only port a series resistor plus a clamp may do, but say so.
References. TPD6S300A §8.3.1 (short-to-VBUS protection, 24 V DC, ringing to ~2×), §9.2.2.4; AN5225 §14.1 (ESD/EOS protection: 20 V-compliant parts for CC and SBU); Type-C Table 3-4 (pin positions).