Skip to content

USB-19 Type-C receptacle variant without the pins the design needs

Severity Status Implementation
warning planned mid, depends on CFG-2, NET-7

Looks at. Receptacle variant (footprint, pin count), what the design uses.

What it catches. A reduced Type-C receptacle (6-pin power-only, 12- or 16-pin USB 2.0) on a port the design uses for more: SBU for an alternate mode or a sideband, TX/RX pairs for USB 3, D+/D− on a power-only part.

Why it matters. Reduced receptacles are popular because they are cheaper and easier to solder, but the missing contacts are simply not there: a signal routed to them in the schematic ends on a pin the footprint lacks or on a pad nothing mates with. It shows up only when the alternate mode or the SuperSpeed link never comes up.

Example. A power-only receptacle (GCT USB4125 class, VBUS, GND, CC1, CC2) chosen for a board that also needs USB 2.0 for firmware updates; or a 16-pin USB 2.0 receptacle (GCT USB4105 class) on a board that routes a DisplayPort alternate mode. B153A uses its receptacle's SBU pins for SWD, which a 16-pin USB 2.0 receptacle still has.

How to check. From the footprint or the part library, which contacts exist; compare with the nets the design puts on that connector (SBU, SuperSpeed pins, D+/D−) and with the project's list of interfaces on the port.

Fix. A receptacle variant with the needed contacts (24-pin full-featured for USB 3 or alternate modes).

References. Type-C Table 3-4 (full 24-pin assignment), Table 3-5 (USB 2.0-only support, unused contacts not connected); GCT, USB4105 - USB 2.0 Connector Type C Horizontal Receptacle gct.co/connector/usb4105 and USB4125 - USB Charging Connector Type C Horizontal Receptacle gct.co/connector/usb4125 (fetched through a headless browser); Wikipedia, USB-C "Receptacles".