ANA-25 Over-specified part a chain cannot use¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | planned | hard, depends on NET-5, NET-10, NET-25, CFG-5, CFG-8 |
Looks at. The chains (NET-25), each stage's figures, the class figure table (CFG-8), the part's grade within its family.
What it catches. A part whose figure on a chain is far better than the chain can use: its contribution referred to the sink is below negligible (default 10 %) of the chain's total on that figure from the other stages and below what the sink resolves, and the part is a precision or premium grade of its class (a 0.05 % 3 ppm/K reference in front of a 10-bit ADC, a zero-drift op-amp after a 1 % divider, a 100 fs oscillator for a 12-bit converter at a low input frequency, a low-noise LDO behind which a switcher path follows).
Why it matters. Premium grades cost several times more and have fewer second sources; where the chain cannot use the figure, it is lost cost. Often it is a leftover of a copied design or a part picked without the chain in view.
Example. A 24-bit-class 1 ppm/K reference for an MCU's 12-bit ADC with ±2 LSB INL: the ADC's own error is a hundred times larger.
How to check. As ANA-24, on the same chains and figures; report a part whose contribution is negligible on every figure it is graded on, naming the stage that sets the chain's total. Only parts the data marks as a precision or premium grade of their class (CFG-8: the grade figures per class, or part-store alternatives in the same family) are reported; without that, nothing is said (an estimate is not enough to call something waste).
Fix. A general grade of the same family, or raise the stage that limits the chain if the precision is wanted.
Relation. ≈ PAS-41 and BOM-19, which judge one circuit block and stay their own checks; this one judges the chain across blocks.
References. As ANA-24.