ANA-6 Op-amp input common-mode range vs the signal

Severity Status Implementation
error planned hard, depends on NET-7, NET-10, CFG-2, RPT-10

Looks at. Op-amp common-mode range (part data), signal range on the inputs.

What it catches. An op-amp whose inputs sit at a voltage outside its input common-mode range: typically a signal at or near the positive rail on a part whose input stage stops 1.5-2 V below it, or a signal at ground on a part that does not include the negative rail.

Why it matters. Outside the common-mode range the input stage runs out of headroom: the gain collapses, the offset grows by orders of magnitude, and some parts invert their output (ANA-8). The circuit looks right on paper because the op-amp symbol has no range on it.

Example. An LM358 on 3.3 V as a high-side current-sense difference amplifier with the inputs at 3.3 V: the LM358 is specified for a common-mode voltage from V− to V+ − 2 V, so 1.3 V is the top of its range and the amplifier reads garbage. On B200A the TLV9004 followers are rail-to-rail input (V− − 0.1 V to V+ + 0.1 V), so their 0-5 V inputs are in range on a 5 V supply, once the supply is there.

How to check. For each op-amp input, the possible voltage range of its net (rails, dividers, signals from connectors with ranges from the project, CFG-2), against the part's common-mode range from the library. Getting the range of an arbitrary signal needs signal following and transfer functions (NET-10, RPT-10); the clear cases (an input on a rail net, or on the high side of a shunt on a rail) come out of the netlist.

Fix. A rail-to-rail input part, an input divider that brings the signal into range, a higher supply for the op-amp, or a current-sense amplifier made for the common-mode range.

References. MT-035 "Op amp input stages" (single-supply and rail-to-rail inputs); LM358 §5.3 (recommended VCM V− to V+ − 2 V); TLV9004 §7.10 (VCM), §8.3.2 (rail-to-rail input); AoE3 chapter 4.