ANA-8 Op-amp input driven beyond its supply with no series resistance

Severity Status Implementation
warning planned mid, depends on NET-5, CFG-2

Looks at. Input source range (connectors, other domains), series parts, op-amp supply.

What it catches. An op-amp input that can see a voltage beyond its supply rails (from a connector, from another power domain, or because the op-amp's own supply can be off) with no resistor between the source and the pin to limit the current.

Why it matters. The inputs are diode-clamped to the rails; above V+ + 0.5 V or below V− − 0.5 V those diodes conduct and only the source impedance limits the current. Datasheets allow about 10 mA; a stiff source delivers amps. Before damage, some parts show phase reversal: the output slams to the opposite rail, which in a control loop is positive feedback. An unpowered op-amp with signals on its inputs is the same case: the clamps then back-power its supply rail.

Example. B200A rev A: +5V0_FLT, the supply of both TLV9004s, has no source, so every IO pin driven by the device under test feeds the op-amp supply through the input clamps. IO0-IO3 have only 255 Ω in series, which a 5 V logic output pushes up to about 17 mA through, above the TLV9004's 10 mA input current rating; RX, SCL and SDA have 1.25 kΩ.

How to check. For each op-amp input, the path back to a connector pin or a net of another rail (NET-5): flag it when no resistor is in the path, or when the resistor cannot hold the current below the part's rating for the voltage the project allows on that pin (CFG-2).

Fix. A series resistor sized for the fault voltage (1-10 kΩ, within the noise budget), external clamps to the rails or a Zener, a part with over-voltage-protected inputs; keep the op-amp powered whenever its inputs can be.

References. MT-036 (output phase reversal, input over-voltage protection); TLV9004 §7.1 (input current ±10 mA, note 2: inputs diode-clamped to the rails); AoE3 chapter 4.