ANA-7 Op-amp output swing vs what the next stage needs¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-7, NET-10, RPT-10 |
Looks at. Op-amp output swing (part data), load, range the next stage needs.
What it catches. An op-amp output expected to reach a level it cannot: 0 V on a single-supply part, or the positive rail, when its output stops tens or hundreds of mV short under the actual load.
Why it matters. "Rail-to-rail output" means within 10-50 mV at light load, more as the load current rises; older outputs stop 1-1.5 V short. A single-supply current or sensor amplifier then cannot show "zero": the low end of the range is lost, and a reading that should be 0 sits at 20 mV forever. Downstream comparators and ADCs inherit the dead zone.
Example. A unidirectional current monitor with REF at ground: the INA181's output swing to ground is specified at 5 mV, but with a +40 µV offset at gain 200 the output cannot go below 8 mV (its own datasheet example), so the first 40 µV of shunt voltage (4 mA on a 10 mΩ shunt) never shows. B200A's TLV9004 followers on 5 V drive 13.7 kΩ / 26.7 kΩ dividers and swing to within about 20 mV of the rails at 10 kΩ, so 0 V and 5 V read as about 13 mV and 3.29 V at the ADC.
How to check. For each op-amp output, the range the next stage expects (ADC full scale, comparator threshold, a project setting), against the output swing of the part at the load the netlist shows. Needs the transfer function of the stage (RPT-10).
Fix. Offset the signal off the rail (REF slightly above ground, a mid-rail bias), a negative supply or charge pump for true zero, a part with a better output, or accept and calibrate the dead zone.
References. INA181 §7.3.5 (rail-to-rail output swing, offset × gain), §8.1.2 (Equations 3 and 4); TLV9004 §8.3.3 (rail-to-rail output); MT-035 "Output stages".