ANA-23 Sense path through copper or a high-TCR part, or not from Kelvin points¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-10, TOOL-2 |
Looks at. Sense path parts, layout geometry.
What it catches. A current measurement whose sense voltage includes copper (a trace used as the shunt, or a stretch of trace or plane between the shunt pad and the sense connection) or a part with a high temperature coefficient (a ferrite, a 0 Ω jumper, a fuse), or whose sense lines leave from the power pads instead of the shunt's Kelvin terminals.
Why it matters. Copper changes its resistance by about 0.39 % per °C: a sense path with copper in it reads 20 % high after a 50 °C rise. A 0 Ω jumper is tens of milliohms with a loose tolerance, comparable to the shunt itself. Where the sense lines attach to the pad matters too: at 5 mΩ, the solder joint and the pad edge are a measurable share.
Example. A 1 mΩ shunt whose sense lines connect to the wide power copper 3 mm from the pads: 0.3 mΩ of copper in series, a 30 % error that grows 0.39 % per °C as the board warms. On a four-terminal shunt the sense pads are separate and the error is gone.
How to check. In the netlist: parts other than the shunt between the shunt and the amplifier inputs (NET-10). The copper part needs the layout: where the sense tracks attach and whether they share copper with the current path (TOOL-2).
Fix. Sense from the shunt's Kelvin pads or the inner edge of its pads with dedicated tracks, use four-terminal shunts at low values, keep jumpers and ferrites out of the sense path, and avoid copper shunts where accuracy matters.
References. INA181 §8.4.1 (Kelvin connection); Wikipedia, Four-terminal sensing; Wikipedia, Electrical resistivity and conductivity (temperature coefficient of annealed copper 3.93 × 10⁻³ /K); ANA-4.