ANA-17 Sensor divider and ADC reference on different sources

Severity Status Implementation
suggestion planned mid, depends on NET-5, NET-12, IMP-9

Looks at. Divider top, ADC reference source.

What it catches. A resistive sensor divider (thermistor, pot, RTD, resistor ladder) excited from a rail while the ADC uses a different reference, or an absolute signal (a divided supply, a sensor with an absolute output) measured against the ADC's own supply as reference.

Why it matters. A divider's output is a fraction of its excitation; an ADC reports the input as a fraction of its reference. When both are the same voltage the rail drops out and only the ratio is measured (ratiometric). When they are different, every percent the rail moves becomes a percent of error: a 3.3 V regulator with 2 % tolerance and ripple is a 2 % error on a temperature that should be exact.

Example. B200A measures 0-5 V signals through a × 0.661 divider into the RP2350 ADC, whose reference is +3V3_VDDA, the buck output through a 0 Ω resistor: the absolute reading inherits the buck's tolerance and ripple. A thermistor divider from the same 3.3 V would cancel it; an absolute measurement needs a reference IC. On B153A the INA181 REF divider runs from the same 3.3 V as VDDA, so its mid-scale offset is ratiometric, as the board notes say.

How to check. For each ADC pin, the top of the divider in front of it (NET-5) against the ADC's reference source: the VREF+ pin's net, or VDDA for parts that use it (part data, IMP-9).

Fix. Excite the sensor from the ADC reference (or measure the excitation on a second channel), or give absolute signals a reference IC.

References. SBAA275 §1.4 (ratiometric measurements); AN2834 §3.2.2 (reference voltage / power supply regulation); RP2350 §6.1.5 (ADC supply ADC_AVDD).