LAY-16 Trace width below the current it carries¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on TOOL-3, CFG-2 |
Looks at. Track widths per net and layer, copper weight, per-net current from the project.
What it catches. A track on a power or high-current net whose width (for its copper weight and layer) is below what the net's current needs for the allowed temperature rise.
Why it matters. Narrow tracks heat up, drop voltage and, at the extreme, fuse. The neck-down where a wide trace meets a small pad or a via is the usual weak spot. The netlist knows nothing about current; the project data has to say how much flows in each net.
Example. A 0.25 mm track on an outer layer of 35 µm (1 oz) copper carrying 2 A to a motor driver: the IPC-2221 formula for external conductors (I = 0.048 · ΔT^0.44 · A^0.725, A in mil²) gives a rise of about 65 °C; a 10 °C rise needs about 0.8 mm. IPC-2152 refines these charts with the board's own heat spreading.
How to check. For each net with a current in the project (CFG-2), find the narrowest track segment and the number of vias in series; compute the width needed per IPC-2152 for the layer and copper weight, and report shortfalls.
Fix. Wider tracks or pours, more vias in parallel where the current changes layers, thicker copper.
References. IPC-2152 (current carrying capacity), IPC-2221B (conductor sizing, the external-conductor formula above), by title.