LAY-17 Decoupling capacitor far from its pin¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on TOOL-3, NET-7 |
Looks at. Which capacitor serves which pin, positions and the routing between them.
What it catches. A decoupling capacitor placed or routed far from the supply pin it is meant for: centimetres away, connected through a long thin track, or with its ground via far from the IC's ground.
Why it matters. A decoupling capacitor works by providing current with a small loop inductance; every millimetre of track adds inductance and makes the capacitor useless at the frequencies it was meant for. A schematic with a 100 nF on every pin and a layout with all of them in a row at the board edge is the classic result.
Example. An MCU with four VDD pins and four 100 nF capacitors placed together 20 mm away near the regulator: at 100 MHz the tracks' inductance dominates and the pins see almost no decoupling; MT-101 asks for the small capacitor "as physically close to the power pins" as possible, with short connections to the ground plane.
How to check. Pair each decoupling capacitor with a supply pin (from the schematic grouping, NET-7, or the nearest pin on the same net); measure the routed path from capacitor pad to pin and from the capacitor's ground pad to a ground via; report pairs above a threshold.
Fix. Place the small capacitor next to its pin on the same side, power path through the capacitor pad to the pin, a short via to ground at the capacitor.
References. MT-101 (local decoupling placement, Figure 6); Ott chapter 11.