LAY-7 Test points without their net name on the silk¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | planned | mid, depends on TOOL-3 |
Looks at. Test point footprints, silk text near them.
What it catches. A test point whose net name (or a short label for it) is not printed next to it.
Why it matters. At bring-up and repair, a test point labelled TP12 sends everyone to the schematic for every probe. With SWCLK, 3V3 or VBUS printed beside it, measurements go faster and fewer probes land on the wrong point (a 20 V rail next to a 1.8 V one is how parts get killed).
Example. On B153A the SWD test points (SWCLK, ...) carried no names; the rev B change list adds silk on the test points.
How to check. For each test point footprint, look for a silk text item in the footprint or near it that contains its net name (or a value field shown on silk, which KiCad's test point footprints can carry).
Fix. Show the net name as silk text next to each test point (a text variable such as ${NET_NAME(1)} in the footprint keeps it in sync).
References. B153 rev B change list (silk on the test points); KiCad PCB "Editing footprint fields".