Skip to content

LAY-25 Hot parts next to sensitive ones

Severity Status Implementation
suggestion planned hard, depends on TOOL-3, RPT-2, NET-7

Looks at. Dissipation per part, positions, the sensitive parts (oscillators, references, ADCs, temperature sensors).

What it catches. Parts that dissipate noticeable power (regulators, power resistors, FETs, LED drivers) placed next to parts whose accuracy depends on temperature: crystals and oscillators, voltage references, ADC front ends, temperature sensors.

Why it matters. Heat spreads through the board's copper. A temperature sensor next to an LDO measures the LDO; a reference next to a power resistor drifts with the load; a crystal's frequency shifts with its temperature. Errors like these show up as "the reading depends on what the board is doing".

Example. A TMP117 (±0.1 °C sensor) placed 3 mm from an LDO dissipating 0.3 W: the sensor reads the LDO's temperature rise. The TMP117 datasheet warns that even the I2C pull-up resistor can be a heat source and asks for some distance between it and the sensor.

How to check. Estimate dissipation per part (from currents and voltages in the project, RPT-2), mark the temperature-sensitive parts (NET-7 roles, part classes), and report pairs closer than a distance that scales with the dissipation.

Fix. Move the sensitive part away, cut the copper between them (a slot or a thermal gap in the pour), or move the hot part to the far side of the board.

References. TMP117 datasheet (SNOSD82D) §10.1 "Layout Guidelines" (ti.com/lit/ds/symlink/tmp117); TI SPRA953, Semiconductor and IC Package Thermal Metrics, Rev. D, §1 (RθJA depends mostly on the PCB, Table 1-1) (ti.com/lit/an/spra953).