Skip to content

LAY-21 Silk without revision, date code or serial blank

Severity Status Implementation
suggestion planned mid, depends on TOOL-3

Looks at. Silk text on the board.

What it catches. A board without its revision on the silk, without a place for a date code, and without a blank area to write a serial number and the assembly revision.

Why it matters. Boards outlive their documentation. A board on the bench with no revision on it makes every bug report ambiguous; a board with no field for a serial number cannot be traced to its test results or rework history. Rev A, rev B and a reworked rev A look the same without it.

Example. A B-series board whose silk shows the project name only: two revisions in the lab, a rework on some rev A units, and no way to tell which board a measurement came from without reading the BOM differences.

How to check. Search the silk text for a revision (rev, ${REVISION} text variable, A/B after the board name) and a date; look for an unfilled rectangle or a labelled field for the serial. Report what is missing.

Fix. Board name and revision on the silk (from the project's title block variables so they stay in sync), a date code, and a blank rectangle for serial number and assembly revision.

References. KiCad PCB "Board setup" (text variables) (docs.kicad.org/9.0/en/pcbnew).