WIRE-5 Power symbol and a signal label with the same name¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on TOOL-3, NET-5 |
Looks at. The schematic (power symbols, labels), the power structure.
What it catches. A net that carries both a power symbol and an ordinary label of the same text, so a signal someone named like a rail is in fact joined to the rail.
Why it matters. In KiCad a power symbol is a global label: every net that touches a VBUS power symbol is one net project-wide. A designer who labels a sense line VBUS (meaning "the VBUS measurement") has just tied the ADC pin to the 5 V rail, or worse, to 20 V after USB PD. The netlist shows one large net and nothing odd about it.
Example. VBAT as the label of the divider output into the ADC, next to the VBAT power symbol of the battery: the ADC pin sits on the battery, 4.2 V into a 3.3 V MCU; the divider resistors are now shorted at one end (SHORT-1).
How to check. In the schematic, nets where a power symbol and a label share a name; in the netlist alone, a rail net (NET-5) with a pin that is an output or an analog input of a signal role is the trace to follow.
Fix. Name the signal for what it is (VBAT_SENSE) and keep rail names for power symbols only.