WIRE-10 Hidden power pins connected by name¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on TOOL-3 |
Looks at. The schematic (symbol pins marked hidden).
What it catches. Symbols with hidden power-input pins, which connect to the net of the same name without a wire on the sheet (KiCad joins them as if a power symbol were there).
Why it matters. The connection exists but is invisible: a reader cannot see which rail a part runs from, and the pin goes to whatever net has that name, which for an old 74-series symbol is VCC and GND. A 3.3 V design with a +5V rail and a VCC net from some other sheet gets the gate powered from the wrong rail, or from a net nobody drives.
Example. A 74HC14 from an old library with hidden VCC/GND pins in a design whose 3.3 V rail is +3V3: the pins join a VCC net that only exists through these hidden pins, with no source. The inverter is unpowered, and the schematic shows nothing.
How to check. Symbols with pins of type power input that are marked hidden; report the net they joined and whether it is a rail with a source.
Fix. Use symbols with visible power pins, or place a separate power unit and wire it.
References. KiCad section "Hidden power pins" ("not recommended in new designs"); Altium ERC "Mismatched Hidden Pin Connections".