WIRE-13 Output pin whose net reaches no input¶
| Severity | Status | Implementation |
|---|---|---|
| warning | runs in better_erc | easy, depends on netlist (NET-10 to look through series resistors |
Data it needs: graph, part classes.
Looks at. Pin types, signal following through series parts.
What it catches. A net driven by an output pin with no input, bidirectional or passive load other than passives to a rail, test points or a connector-free dead end.
Why it matters. An output that drives nothing is a function that was designed and then lost on the way: the consumer was deleted, renamed (WIRE-1), or sits on another sheet behind a broken sheet pin (WIRE-4). Sometimes it is on purpose (a spare kept for rework), and then the review should say so.
Example. On B200A the last shift register's serial output EX4_QH_CHK (U1404 QH') goes to TP1401 only: the MCU cannot read the 32-bit chain back to verify it loaded. A deliberate choice there, and exactly the kind of net this check lists for a decision.
How to check. For each output pin, follow the net through series resistors (NET-10) and list nets where no other pin is an input, bidirectional or an IC pin of unknown type.
Fix. Connect the consumer, or note why the output is spare (and add a test point if it should be measurable).
References. KiCad sections "Pin electrical types" and "ERC violation severity and pin conflicts map"; catalogue WIRE-1, WIRE-4.
Settings¶
Set them in the project file under [checks."WIRE-13"], or for one run with --set WIRE-13.NAME=VALUE.
| Setting | Default | Meaning |
|---|---|---|
WIRE-13.max_hops |
3 | how many series parts (R, C, L, ferrite, jumper) the search for a load looks through |
Test schematics¶
Each schematic below is in test_schematics/sources. The block under it is what berc check --only WIRE-13 reports on it.
wire-13_output_to_nowhere¶
warning WIRE-13 #441 /QH_CHK: driven by U1.9 (QH') and taken by no input, only passives, test points or other outputs
net /QH_CHK, pin U1.9
fix: connect the consumer, or note why the output is spare (a test point if it should be measurable)
WIRE-13 also fires on the test schematics of other checks: bom-4_placement, drv-7_half_bridge_snubber, hs-9_choke_on_lanes, io-16_pull_up_and_down, leak-1_rail_dividers, name-4_uart_names, pin-3_unprotected_outputs, pin-4_unfused_inputs, pin-6_unfiltered_inputs, rail-18_parallel_regulators.