Severity Status Implementation
error planned mid, depends on TOOL-3

Looks at. The schematic (no-connect flags, wires).

What it catches. A pin with a no-connect flag that is also connected to a wire, a label or another pin.

Why it matters. The flag says "deliberately unconnected", the wire says the opposite. One of the two is stale: either the pin was later put to use and the flag forgotten (harmless to the copper, but it hides the next real open pin from review), or the flag is right and the wire joins something that must not be there.

Example. An unused comparator output flagged no-connect, later wired to a spare GPIO for a test: the flag stays and the review checklist "all NC pins are intended" passes over a pin that now drives a net.

How to check. No-connect flag positions against pin ends that also touch a wire or label; KiCad reports it too.

Fix. Delete the flag or the wire, whichever is stale.

References. KiCad "A pin with a "no connection" flag is connected" (no_connect_connected), section "No-connection flags".