Skip to content

WIRE-12 Same label text in different scopes

Severity Status Implementation
error planned mid, depends on TOOL-3

Looks at. The schematic (label scopes).

What it catches. One label text used in two scopes: a local label and a global label, or a hierarchical sheet pin and a global label, of the same name.

Why it matters. Whether such labels join is a tool rule, and the rules differ between tools and versions: a designer from one tool assumes they are one net, the tool keeps them apart (or the other way round). Either the signal is open, or two signals that were meant to be separate are shorted. Moving the design between tools changes the netlist with no visible edit.

Example. A local SDA on a sensor sheet and a global SDA from the MCU sheet: in KiCad they are separate nets and the sensor has no bus; renamed to a global label it joins, but so does the unrelated local SDA of a second, isolated bus.

How to check. Collect label texts with their scope per sheet; report a text that appears with two scopes.

Fix. One scope per name: global for cross-sheet signals, local with a sheet-specific name for the rest.

References. KiCad "Local and global labels have the same name" (same_local_global_label), section "Net name assignment rules"; Altium ERC "Nets with multiple names".