Skip to content

WIRE-15 Four-way junction or a label over several wires

Severity Status Implementation
suggestion planned mid, depends on TOOL-3

Looks at. The schematic (wire geometry, junctions).

What it catches. A junction where four wires meet at one point, and a label whose anchor sits where several wires meet so it is not clear which it names.

Why it matters. On paper and in PDF prints, a four-way junction with a small dot is easy to misread as two crossing wires (and a crossing as a junction, when the dot is lost in printing). Reviewers then argue about a net the netlist is already sure about. Offsetting the joins into two T-junctions makes the drawing say one thing.

Example. The ground net of an op-amp stage drawn as a cross with a 0.5 mm dot: in a printed review the dot disappears and the reviewer marks "feedback not grounded".

How to check. Count wire ends per junction point; four or more is a finding. Labels whose anchor touches more than one wire segment are reported with it.

Fix. Split into two T-junctions; move the label onto a single segment.

References. KiCad "Four connection points are joined together" (four_way_junction, off by default), "Label connects more than one wire" (label_multiple_wires), section "Wire junctions".