PAS-10 Dielectric absorption where a capacitor must forget its past voltage¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-7, NET-23, NET-24 |
Looks at. The capacitor's role (hold, integrator reset, peak detector, charge measurement) and technology.
What it catches. Class 2 ceramics and electrolytics as the hold capacitor of a sample-and-hold, the capacitor of an integrator that is reset by a switch, a peak detector's storage capacitor, or a capacitor whose charge is measured.
Why it matters. A dielectric that has been charged keeps part of that charge in its slow polarisation: after a short discharge the voltage creeps back by a fraction of the old value. ADI's table: polypropylene and polystyrene 0.001 to 0.02 %, NP0 ceramic under 0.1 %, high-K ceramic 0.2 % and more, tantalum 1 to 5 %, some electrolytics 10 % or more. A sample-and-hold then remembers the previous sample, an integrator restarts from an offset.
Example. A 100 nF X7R as the integrating capacitor of a charge amplifier reset every millisecond: each reading carries a few tenths of a percent of the last one, half an LSB at 8 bits.
How to check. For capacitors in the roles Hold, Integrator (with a reset switch across it) and PeakDetector, report technologies with dielectric absorption above a threshold (default 0.1 %: anything but class 1 ceramic and PP, PS or PTFE film).
Fix. Polypropylene, polystyrene or PTFE film; C0G for small values.
References. ADI-BLD; VIS-FILM (PET 0.2 %, PP 0.05 %, PP for sample and hold).