PAS-4 Hold-up or backup capacitor whose own leakage drains what it holds¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-7, NET-23, NET-24, CFG-2, RPT-26 |
Looks at. The capacitor's leakage or self-discharge, the load it holds and the hold time wanted.
What it catches. A capacitor that must hold a voltage for a long time (an RTC's VBAT supercapacitor, a memory hold-up, a sample-and-hold or peak detector capacitor, a timer's storage capacitor) whose own leakage or self-discharge is comparable to the current it is meant to supply or the droop allowed.
Why it matters. The hold time is computed as C × ΔV / Iload; the capacitor's leakage adds to Iload. A supercapacitor's leakage current after charging is microamps, the same order as an RTC's backup current; an electrolytic's is similar. The board then keeps time for hours instead of days.
Example. A 0.1 F supercapacitor on a 1 µA RTC backup pin for a computed day of hold-up: with a few µA of leakage it lasts a few hours.
How to check. For capacitors in the role Hold (VBAT of an RTC with no battery, a hold-up node, a sample-hold), compare the leakage at the held voltage with the load current from the pin's facts (or the project's hold-up time), and report when leakage is above a fraction (default 20 %) of the load.
Fix. A lower-leakage part (a lithium cell, a low-leakage supercapacitor series, a film or C0G capacitor for sample-and-hold), or a hold time computed with the leakage included.
References. EAT-SC (supercapacitor leakage and self-discharge); ADI-BLD (sample-and-hold capacitor choice).