PAS-37 Coupled inductor and topology do not match¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-6, NET-7, NET-24, CFG-5 |
Looks at. The converter topology (part data), whether the magnetics are one coupled part or two inductors, its coupling and ratio.
What it catches. A SEPIC, Cuk, Zeta or flyback whose datasheet design (or the inductance computed for it) assumes a coupled inductor, fitted with two separate inductors, or the other way round; a coupled inductor whose ratio or coupling is not what the topology needs (1:1 for SEPIC and Zeta, 1:N for a flyback, loose coupling for some SEPIC designs).
Why it matters. With close coupling the ripple current is shared and the required inductance per winding halves (Coilcraft: two 22 µH singles become one 11 µH coupled part); fitted with two separate parts of the coupled value, the ripple doubles. A coupled part's saturation rating applies to the sum of both windings' currents and its RMS rating differs for one winding or both.
Example. A SEPIC designed with a 10 µH 1:1 coupled inductor rebuilt with two 10 µH single inductors: peak currents beyond the switch limit.
How to check. From the regulator's topology and its required magnetics, compare with the inductors found on its switching nodes (one part with four pins and a coupling, or two parts), and the coupled part's ratio and coupling.
Fix. The magnetics the design assumes, or the inductance recomputed for what is fitted.
References. CC639; CCcpl.