PAS-21 Capacitor across mains or an isolation barrier that is not safety rated¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on NET-5, NET-23, NET-24, CFG-2 |
Looks at. Which nets are mains or the two sides of a barrier, the capacitor's safety class.
What it catches. A capacitor between mains conductors (line to line, line to neutral) that is not X-class, or between a mains or hazardous side and protective earth or the touchable side of an isolation barrier that is not Y-class (Y1 for reinforced isolation, Y2 for basic).
Why it matters. IEC 60384-14 defines X capacitors to survive mains surges and fail safely (open, self-healing film), and Y capacitors to never fail short, because a shorted Y capacitor puts mains on the user. An ordinary MLCC or film capacitor of a high enough voltage rating is neither; a crack or breakdown is a short. Isolation ratings of the barrier as a whole are GND-6's; whether a Y capacitor should be there is GND-2's.
Example. A 4.7 nF 3 kV general-purpose MLCC across an isolated converter's barrier as the EMI capacitor: it passes the voltage rating and is not a Y capacitor.
How to check. For capacitors with role MainsX (both nets mains, by project or net class) or BarrierY (nets on two isolation sides, GND), report a missing or wrong safety class.
Fix. An X2 film capacitor across the line, a Y1 or Y2 ceramic or film capacitor (film, single-disc ceramic or safety-certified MLCC families) across the barrier.
References. VIS-SAFETY (IEC 60384-14 classes: X1 4 kV, X2 2.5 kV, Y1 8 kV, Y2 5 kV impulse); VIS-FILM.