PAS-11 Class 3 dielectric (Y5V, Z5U) where capacitance matters¶
| Severity | Status | Implementation |
|---|---|---|
| suggestion | planned | mid, depends on NET-24, CFG-7 |
Looks at. The capacitor's dielectric.
What it catches. Y5V, Z5U and similar class 3 capacitors anywhere their capacitance is relied on: decoupling a part with a minimum, a regulator's input or output, a filter, a timer.
Why it matters. Y5V is specified +22/−82 % over −30 to 85 °C, loses most of its capacitance at a DC bias, and ages several percent per decade-hour: a 10 µF part can be 2 µF at temperature and bias. It is cheap and almost never the right choice on a modern board.
Example. A 10 µF Y5V on an LDO's output that needs at least 1 µF: fine on the bench at room temperature, unstable in the cold.
How to check. Report every class 3 dielectric whose role is not Bulk with an explicit waiver; with the role known, raise to a warning where a minimum capacitance applies (RAIL-21, DEC-6).
Fix. X5R or X7R of a higher rated voltage or larger case.
References. ADI-CER (a 4.7 µF Y5V 0603 at 5 V is 0.33 µF); MUR-VOLT; MUR-GRM.