PAS-29 NTC inrush limiter without a bypass or on a supply that restarts quickly

Severity Status Implementation
suggestion planned mid, depends on NET-5, NET-23

Looks at. The NTC's position (series in a power input), whether it is bypassed.

What it catches. A power NTC in series with a supply input to limit inrush, with no relay or FET that bypasses it once running, or on a supply that can be switched off and on within the NTC's cooling time.

Why it matters. An inrush NTC limits current only while it is cold. Running, it sits hot at a low resistance and dissipates continuously; switched off and on quickly it is still hot and does not limit the second inrush. Its energy rating is finite (Vishay AS352R035: 700 J recommended, 1400 J to failure).

Example. A 2 Ω NTC in a 48 V input of a motor controller that is power-cycled by a contactor: the second inrush after a short off-time blows the fuse.

How to check. For NTCs in the role InrushLimiter, report when no switch element (relay contact, FET) is in parallel; the energy check against its rating is RATE-27.

Fix. A bypass relay or FET that shorts the NTC after start-up, or an active inrush limiter.

References. V-ICL.